Project
|
Type
|
Products Used/Method
|
Engineers/Contractors
|
Status
|
|
Toronto
Transit
Commission
Toronto,
Canada
|
Sheppard Ave
Subway Tunnels
Segments
|
Insert Used: 3/4” Insert
Application: Segment Anchoring
Quantity: 212,000
Diameter: 17.5 ft
Length: 11,600 ft
|
Engineer: Hatch Assoc.
Precaster: Concast Guelph, Ontario
Contractor: McNally PCL Foundation J.V. Ltd.
|
Started 1995
Completed 1998
|
|
LA
Water District
West
Hollywood Tunnel
Los
Angeles, CA
|
Water Tunnel
Segments
|
Length: 4,593 ft
Application: Segment Anchoring
Insert Used: 5/8”
Quantity: 32,000
|
Engineer: Parsons Scientific
Contractor: Elmore Wood
Tel: (818)898-1007
|
Completed 2000
|
|
North
City Metro
Interceptor
Tunnel
San
Diego, CA
|
Sewage Outfall
Tunnel Segments
|
Insert Used: 3/4” Insert
Application: Segment Anchoring
Quantity: 23,000
Diameter: 15 ft
|
Engineer: Parsons Engineering & Science
Contractor: McNally PCL Foundation J.V. Ltd.
Contact: Pat Newcomb /Project Manager
Tel: 509-636-2086
|
Completed 1997
|
|
Tren
Urbano Transit
System
Puerto
Rico
|
Rio Piedras
Transit Tunnel
Segments
|
Insert Used: 1” Insert
Application: Segment Anchoring
Quantity: 20,000
Diameter: 21 ft
Length: 3,500 ft
|
Engineer: Kiewit
Contractor: Marmolejo Cont.
Contact: Mehdi Ghazi/ Project Manager
Tel: 503-630-6379
|
Completed
|
|
Waukesha
Water Tunnel
Waukesha,
WI
|
Water tunnel
|
Insert Used: 3/4”” Insert
Application: Segment Anchoring
Quantity: 28,000
Diameter: 14 ft
Length: NA
|
Engineer: N/A
Segments: CSI-Waukesha JV
Contact: John Hart
Tel: (703) 946-7330
|
Completed
|
|
Big
Walnut Augmentation/
Rickenbacher
Interceptor
Columbus,
OH
|
Outfall Tunnel
Segments
|
Insert Used: 3/4” Insert
Application: Segment Anchoring
Quantity: 60,000
Diameter: 14 ft
Length: 21,400 ft
|
Engineer: URS Corp.
Precaster: CSI/Tunnel Systems
Contractor: JayDee / Michaels / Traylor Bros.
Contact: John Hart
|
Started 2004
Completed 2006
|
|
Metro
Caracas
Caracas
Venezuela
|
Transit Tunnel
Segments
|
Insert used: 3/4” Insert
Application: Segment Anchoring
Diameter: 14 Ft.
Quantity: 100,000
|
Contractor: Ghella Group
Contact: Vito Di Corato
|
Started 2004
Completed 2006
|
|
Moscow
Metro Extension
Moscow,
Russia
|
Transit Tunnel
Segments
|
Insert Used: 20mm Insert
Application: Segment Anchoring
Quantity: 17,900
Diameter: 4.27 meters
|
Customer: Lovat, Inc
Precaster: Charcon Tunnels, UK
Contact: Howard Lloyd
Tel: 011441623754493
|
Completed 2004
|
|
23rd
Avenue Storage
Edmonton,
Alberta
|
Water Tunnel
Segments
|
Insert Used: 1” Insert
Application: Segment Anchoring
Quantity: 13,000
Diameter: 3.2 meter
Length: 1.2 km
|
Customer: Aecon/McNally JV
Contractor:
Contact: Mehdi Ghazi/ Project Manager
Tel: 503-630-6379
|
Completed 2004
|
|
Arrowhead
Tunnel Project
San
Bernardino, CA
|
Water tunnel
|
Insert Used: 1/2” casting plugs
Application: Utility hangers
Quantity: 75,000
Diameter: NA
Length: 43,000 ft.
|
Customer: Traylor/Shea/ Ghazi
Contact: Mhedi Ghazi
|
Completed 2006
|
|
Brightwater
East Project
Seattle
WA
|
Outfall Tunnel
Segments
|
Insert used: 3/4” Insert
Application: Segment Anchoring
Diameter: NA
Quantity: 34,000
|
Engineer: Jacobs Associates
Precaster: CSI/Tunnel Systems/Hanson JV
Contractor: Kenny / Shea / Traylor .
Contact: John Hart
|
Started 2007
|